Skip to content

Clarify PVWatts DC and inverter documentation #1785

New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Merged
merged 3 commits into from
Jun 27, 2023
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
7 changes: 6 additions & 1 deletion pvlib/inverter.py
Original file line number Diff line number Diff line change
Expand Up @@ -335,7 +335,7 @@ def pvwatts(pdc, pdc0, eta_inv_nom=0.96, eta_inv_ref=0.9637):
NREL's PVWatts inverter model.

The PVWatts inverter model [1]_ calculates inverter efficiency :math:`\eta`
as a function of input DC power
as a function of input DC power :math:`P_{dc}`

.. math::

Expand Down Expand Up @@ -369,6 +369,10 @@ def pvwatts(pdc, pdc0, eta_inv_nom=0.96, eta_inv_ref=0.9637):

Notes
-----
When sourcing ``pdc`` from pvlib functions
(e.g. :py:func:`pvlib.pvsystem.pvwatts_dc`) their DC power output is in W,
and ``pdc0`` should have the same unit (W).

Note that ``pdc0`` is also used as a symbol in
:py:func:`pvlib.pvsystem.pvwatts_dc`. ``pdc0`` in this function refers to
the DC power input limit of the inverter. ``pdc0`` in
Expand All @@ -393,6 +397,7 @@ def pvwatts(pdc, pdc0, eta_inv_nom=0.96, eta_inv_ref=0.9637):
pdc_neq_0 = ~np.equal(pdc, 0)

# eta < 0 if zeta < 0.006. power_ac is forced to be >= 0 below. GH 541
# In some published versions of [1] the parentheses are missing
eta = eta_inv_nom / eta_inv_ref * (
-0.0162 * zeta - np.divide(0.0059, zeta, out=eta, where=pdc_neq_0)
+ 0.9858) # noQA: W503
Copy link
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

What's the difference between this code and the equation in the reference? I can't see it:

image

Copy link
Member Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

The parentheses are missing in this copy: https://www.nrel.gov/docs/fy14osti/62641.pdf Which copy did you open?

Copy link
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Oh interesting. I was looking at the PDF linked in the pvlib.inverter.pvwatts docstring: https://pvwatts.nrel.gov/downloads/pvwattsv5.pdf

Good to know there are multiple non-identical versions of that PDF. I wonder if there are any other differences...

Expand Down
8 changes: 4 additions & 4 deletions pvlib/pvsystem.py
Original file line number Diff line number Diff line change
Expand Up @@ -2809,9 +2809,9 @@ def pvwatts_dc(g_poa_effective, temp_cell, pdc0, gamma_pdc, temp_ref=25.):

P_{dc} = \frac{G_{poa eff}}{1000} P_{dc0} ( 1 + \gamma_{pdc} (T_{cell} - T_{ref}))

Note that the pdc0 is also used as a symbol in
:py:func:`pvlib.inverter.pvwatts`. pdc0 in this function refers to the DC
power of the modules at reference conditions. pdc0 in
Note that ``pdc0`` is also used as a symbol in
:py:func:`pvlib.inverter.pvwatts`. ``pdc0`` in this function refers to the DC
power of the modules at reference conditions. ``pdc0`` in
:py:func:`pvlib.inverter.pvwatts` refers to the DC power input limit of
the inverter.

Expand All @@ -2836,7 +2836,7 @@ def pvwatts_dc(g_poa_effective, temp_cell, pdc0, gamma_pdc, temp_ref=25.):
Returns
-------
pdc: numeric
DC power.
DC power. [W]