Notifications
You must be signed in to change notification settings - Fork 18.1k
net: TestInterfaceHardwareAddrWithWmic fails #23153
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Comments
Thanks for spotting this! @alexbrainman which version of Windows is this machine on? Can you run Trying to track down the mapping between wmic parameters and |
I have VirtualBox installed. Alex |
Change https://golang.org/cl/84696 mentions this issue: |
Is this just a bug/kludge in the Microsoft? On my system the interface is called "Local Area Connection 14" and ipconfig shows a "mac address" of 00..0e. Which is just another way to say 14... |
I do not know how this things were decided by Microsoft? @mattn can you, please, run net.TestInterfaceHardwareAddrWithWmic on current tip. That code got changed recently, and I am worried about interface names that have non-English characters in it. I remember that test broke for you in the past. Thank you. Alex |
@alexbrainman wmic command seems not list with names if the interface is down. Anyone, could you please try this? diff --git a/src/net/net_windows_test.go b/src/net/net_windows_test.go
index ab09cdb28a..5c227d81b4 100644
--- a/src/net/net_windows_test.go
+++ b/src/net/net_windows_test.go
@@ -523,6 +523,10 @@ func TestInterfaceHardwareAddrWithWmic(t *testing.T) {
// no MAC address for loopback interfaces
continue
}
+ if ifi.Flags&FlagUp == 0 {
+ // interface is not up
+ continue
+ }
goMacToName[ifi.HardwareAddr.String()] = ifi.Name
}
On my environment, some of NIC name have multi-byte strings. So tests always fail. (Yes, this is known issue) |
Ah, I misreaded. Sorry. Enabled flag can be used.
Yes, As you mentioned about non-english interface names, I still have problem. |
@alexbrainman Good news. wmic command output UTF-16 when the output is a file. It return DBCS when output is a pipe. So writing file should work. Could you please add runWmic? diff --git a/src/net/net_windows_test.go b/src/net/net_windows_test.go
index ab09cdb28a..ed02ae7e62 100644
--- a/src/net/net_windows_test.go
+++ b/src/net/net_windows_test.go
@@ -18,6 +18,7 @@ import (
"syscall"
"testing"
"time"
+ "unsafe"
)
func toErrno(err error) (syscall.Errno, bool) {
@@ -512,6 +513,29 @@ func contains(needle string, haystack []string) bool {
return false
}
+func runWmic(args ...string) ([]byte, error) {
+ f, err := ioutil.TempFile("", "wmic")
+ if err != nil {
+ return nil, err
+ }
+ defer os.Remove(f.Name())
+ cmd := exec.Command(args[0], args[1:]...)
+ cmd.Stdout = f
+ err = cmd.Run()
+ f.Close()
+ if err != nil {
+ return nil, err
+ }
+ b, err := ioutil.ReadFile(f.Name())
+ if err != nil {
+ return nil, err
+ }
+ if len(b) >= 3 && b[0] == 0xEF && b[1] == 0xBB && b[2] == 0xBF {
+ b = b[3:]
+ }
+ return []byte(syscall.UTF16ToString(*(*[]uint16)(unsafe.Pointer(&b)))), nil
+}
+
func TestInterfaceHardwareAddrWithWmic(t *testing.T) {
ift, err := Interfaces()
if err != nil {
@@ -523,6 +547,10 @@ func TestInterfaceHardwareAddrWithWmic(t *testing.T) {
// no MAC address for loopback interfaces
continue
}
+ if ifi.Flags&FlagUp == 0 {
+ // interface is not up
+ continue
+ }
goMacToName[ifi.HardwareAddr.String()] = ifi.Name
}
@@ -533,7 +561,7 @@ func TestInterfaceHardwareAddrWithWmic(t *testing.T) {
//SERVER-2008R2-V,42:01:0A:F0:00:18,Local Area Connection
//SERVER-2008R2-V,42:01:0A:F0:00:18,Duplicate Adapter
//SERVER-2008R2-V,20:41:53:59:4E:FF,
- out, err := exec.Command("wmic", "nic", "get", "MACAddress,NetConnectionID", "/format:csv").CombinedOutput()
+ out, err := runWmic("wmic", "nic", "get", "MACAddress,NetConnectionID", "/format:csv")
if err != nil {
t.Fatal(err)
} |
Thank you for confirming. Sorry about the break. I will let @johnsonj decide what to do about CL 84696, and then we need to fix your problem with non-English names. I suggest you create new issue for non-English names, so we don't forget to fix it before go1.10 is released. Thank you. Alex |
Change https://golang.org/cl/85315 mentions this issue: |
this solution as it stands doesn't work with non-english device names (#23191 (which has a fix)) and names some devices differently (#23153) probably due to the fact that this test previously only ran on Server 2008. Re-opens #20073 Change-Id: I5c36774ddd85ac07620b4015372d564acbb169ad Reviewed-on: https://go-review.googlesource.com/85315 Reviewed-by: Alex Brainman <[email protected]>
Change https://golang.org/cl/84935 mentions this issue: |
I'm not quite sure what is happening with this issue. It says that there is a test failure, but it seems that the test was reverted. What is left to do here? Thanks. |
TestInterfaceHardwareAddrWithWmic is removed now, so this issue can be closed. We still have issue #20073 opened - TestInterfaceHardwareAddrWithWmic was added to fix #20073. Thank you. Alex |
Thanks. |
What version of Go are you using (
go version
)?go version devel +98443ecd0a Fri Dec 15 21:57:27 2017 +0000 windows/amd64
Does this issue reproduce with the latest release?
Yes, it does.
What operating system and processor architecture are you using (
go env
)?set GOARCH=amd64
set GOBIN=
set GOCACHE=C:\Users\Alex\AppData\Local\go-build
set GOEXE=.exe
set GOHOSTARCH=amd64
set GOHOSTOS=windows
set GOOS=windows
set GOPATH=c:\users\alex\dev
set GORACE=
set GOROOT=c:\users\alex\dev\go
set GOTMPDIR=
set GOTOOLDIR=c:\users\alex\dev\go\pkg\tool\windows_amd64
set GCCGO=gccgo
set CC=gcc
set CXX=g++
set CGO_ENABLED=1
set CGO_CFLAGS=-g -O2
set CGO_CPPFLAGS=
set CGO_CXXFLAGS=-g -O2
set CGO_FFLAGS=-g -O2
set CGO_LDFLAGS=-g -O2
set PKG_CONFIG=pkg-config
set GOGCCFLAGS=-m64 -mthreads -fmessage-length=0 -fdebug-prefix-map=C:\Users\Alex\AppData\Local\Temp\go-build981970258=/tmp/go-build -gno-record-gcc-switches
What did you do?
I run
go test -run=TestInterfaceHardwareAddrWithWmic net
command.What did you expect to see?
What did you see instead?
Alex
The text was updated successfully, but these errors were encountered: