@@ -56,7 +56,7 @@ US 021: Accepted, fixed in 50e55ce9.
56
56
* Split index entries to "block (execution)" and "block (statement)".
57
57
* Also added the statement form to Clause 3, Terms and Definitions.
58
58
59
- GB 022: Accepted, fixed in 8cc6bd34.
59
+ GB 022: Accepted with modifications , fixed in 8cc6bd34.
60
60
61
61
* The relevant change had already been made to [ using.headers] ,
62
62
but this corresponding change was missed.
@@ -137,7 +137,7 @@ US 155: Propose accepting; **LWG to approve direction**
137
137
JP 177: Accepted, fixed in 8be40ff0.
138
138
139
139
* Replaces a reference to ISO/IEC/IEEE 60599 with a reference to the intended ISO/IEC/IEEE 60559.
140
- * IEC 60599 is "Mineral oil filled electrical equipment in service --
140
+ * IEC 60599 is "Mineral oil- filled electrical equipment in service --
141
141
guidance on the interpretation of dissolved and free gases analysis"
142
142
* ISO/IEC/IEEE 60559 is "Information Technology - Microprocessor Systems --
143
143
Floating-Point Arithmetic"
@@ -191,12 +191,12 @@ US 325: No consensus for change.
191
191
but will reconsider the organization of the standard library clauses
192
192
for a future standard.
193
193
194
- US 327: ** SG8 / LEWG to handle issue**
194
+ US 327: ** SG6 / LEWG to handle issue**
195
195
196
196
* The proposed change is not editorial.
197
197
* Duplicate of PL 326
198
198
199
- US 328: ** SG8 / LEWG to handle issue**
199
+ US 328: ** SG6 / LEWG to handle issue**
200
200
201
201
* The proposed change is not editorial.
202
202
0 commit comments